UK188-E PVC floor adhesive
A ready-to-use water-based ternary copolymer for resilient coverings. High initial tack and high final bond, so sheet goes down without a long open time and without lifting at seams.
Suitable for
- PVC sheet flooring and PVC tiles.
- Impervious-backed carpet and quartz (PVC) tile.
- Rubber flooring up to 2 mm thick.
- Floors, walls and wall cladding, including coved skirting.
Not intended for
- Rubber flooring above 2 mm — outside the tested scope; use a dedicated rubber adhesive.
- Wet, frozen or contaminated substrates.
- Any substrate not listed, without checking with us first.
| Base | Water-based ternary copolymer |
|---|---|
| Colour | Milky white |
| Form | Thixotropic gel — ready to use, no dilution |
| Coverage | 75–80 m² per 20 kg pail (250–270 g/m²) |
| Open time | 20–30 min at 20 °C / 55% RH |
| Ready to lay when | The adhesive strings and shows strong tack on finger contact |
| Foot traffic | After 24 h minimum |
| Heat resistance | Up to 50 °C — suitable over underfloor heating |
| Storage | 5–35 °C, frost-free — do not use if the product has frozen |
| Shelf life | 12 months at room temperature, sealed pail |
| Packing | 20 kg net pail |
Tested performance
| Property | Standard | Requirement | Result |
|---|---|---|---|
| Appearance | JC/T 550-2019 | Uniform, free of lumps | Pass |
| Trowelability | JC/T 550-2019 | Spreads easily, combing lines stand | Pass |
| 90° peel strength, standard condition | JC/T 550-2019 | ≥ 1.0 N/mm | 2.3 N/mm |
| Shear strength, standard condition | JC/T 550-2019 | ≥ 0.3 MPa | 0.5 MPa |
| Free formaldehyde | GB 18583-2008 Annex A | ≤ 1.0 g/kg | Not detected (< 0.05 g/kg) |
Judged against JC/T 550-2019 as a normal-type adhesive, and GB 18583-2008 Annex A for free formaldehyde. Not a full performance test. Other clauses of either standard can be tested on request.
How to run it
- Do not dilute. Stir briefly before use.
- Spread with an A2 or A3 notched trowel, constant angle, even full-bed coat.
- Leave 20–30 min. Laying starts when the adhesive strings and shows strong tack — not before.
- Push out trapped air from the centre outwards with a cork or soft board.
- Roll the whole area with a 50 kg roller, across then along, within the open time.
- No foot traffic for 24 h; no water washing of the finished floor in the first 24 h.
Questions we get asked
Can it be used over underfloor heating?
Yes. Heat resistance is up to 50 °C, which covers underfloor heating systems.
How long before the floor can be walked on?
24 hours minimum. Do not wash the floor with water during that time.
Is it suitable for rubber flooring?
Up to 2 mm only. Above that it falls outside the tested scope and a dedicated rubber adhesive should be used.
Does it contain formaldehyde?
Free formaldehyde was not detected (< 0.05 g/kg) against GB 18583-2008 Annex A.
How much does a 20 kg pail cover?
75–80 m² at 250–270 g/m². Add an allowance for porous substrates and cutting waste.
Need the UK188-E datasheet?
Ask for the ZERYON-issued TDS and a sample pail for your substrate.