Flooring adhesives

Five water-based grades for resilient flooring, plus two substrate primers. Each grade is tuned to one job — the covering, the substrate, and how long you need before the film skins.

Not one adhesive for everything. Picking the wrong grade is the most common cause of a floor lifting at the seams a year later.

Choose by covering

Grade selection
Vinyl sheet, full bondU35070–95 m² per 20 L10–30 min
Vinyl tile, LVT, glue-down SPCU30090–110 m² per 20 Lpressure-sensitive film
Conductive / ESD vinylU300D200–250 g/m²10–30 min
Linoleum sheet & tileU770320–360 g/m²0–5 min
PVC sheet, tile, impervious-backed carpetUK188-E75–80 m² per 20 kg20–30 min

The five grades

Volumes shown are per pail at the stated consumption. Add 5–10% for porous substrates and cutting waste.

Where these are used

  • Healthcare & laboratories — sheet vinyl in wards, conductive grades where static control is specified.
  • Education & offices — tile and LVT over large areas, glue-down SPC where movement joints allow.
  • Retail & hospitality — linoleum and PVC sheet, pattern-matched across wide runs.
  • Industrial & transport — heavy-duty sheet over prepared screed, ESD systems over copper earthing.

What we need to specify a grade

  • Covering — type and backing of the floor covering.
  • Substrate — screed, plywood, existing covering; surface and moisture condition.
  • Site — ambient temperature and humidity during installation and curing.
  • Requirement — standard duty, or a specific property such as static dissipation.

Questions we get asked

Which grade do I use for LVT?

U300. It is pressure-sensitive, so the plank is laid into a tacky film rather than a wet bed, and can be lifted and re-set during installation.

Do I always need a primer?

On absorbent cement and gypsum, yes — without it the adhesive dries too fast and fails at the interface. Non-absorbent surfaces such as ceramic tile take GP266 instead.

Can one adhesive cover the whole range?

No. The laying windows differ by an order of magnitude — U770 is 0–5 minutes, UK188-E is 20–30. Using one grade across all coverings is how floors fail at the seams.

What coverage should I budget?

Take the figure from the selection table and add 5–10%. Porous screeds drink noticeably more than the nominal rate.

Documentation Technical data sheets, safety data sheets and the declaration of conformity for each grade are issued on request. Tell us the grade and the destination country and we send the matching set.

Not sure which grade fits?

Send the covering type and the substrate, and we will point you to the right sheet.

Ask a technical question